Error codes and LED signals
Report errors, understand LED signals and take safe next steps
LED signals
Find the complete mapping of all colours and lighting patterns in the LED colour legend.
- Red pulsing, entire ring: An error has occurred. Check the details in the app.
- Red pulsing, top: The dirt filter is clogged. Clean it and reset the message in the app.
- White pulsing: Recovery mode; the Wi-Fi credentials have been deleted.
Error messages in the app
| Message | Meaning | Next step |
|---|---|---|
| Device unreachable | No connection between cloud and device | Check power supply and Wi-Fi |
| Sensor error | No valid sensor data | Check the sensor and data cable |
| Filter maintenance required | Filter must be cleaned | Clean the filter and reset the reminder |
| Firmware update failed | Update was not transferred completely | Try again with a stable Wi-Fi connection |
Active WaterGuard Refill errors
The product-wide error list is filtered here for WaterGuard Refill; not all global codes apply to Refill.
Note about the error list
The error codes are organised by observable problems. When an error occurs, start with the relevant troubleshooting article and use the error code for classification.
| Code | Meaning | Next step |
|---|---|---|
| 100 | Maximum refill duration exceeded | See the explanation and diagnosis under Refill problems. Confirm or reset the error in the dashboard after resolving it. |
| 202 | Tank not defined | Define the tank in the app or web dashboard. Without a tank, no correct percentage level or volume-based tank content can be calculated. |
| 0 | System ready for operation | Not an error. The system is operating correctly and there are no active errors. |
Reserved sensor errors – automatic detection being prepared
The following codes are intended for a future diagnostic function but are not yet automatically evaluated in the current WaterGuard Refill functionality. They are therefore not detected reliably.
Automatic detection being prepared
This error code is already intended for a future diagnostic function but is not yet automatically evaluated in the current WaterGuard Refill functionality.
| Code | Meaning | Status |
|---|---|---|
| 218 | Level measurement unstable – readings fluctuate outside the permitted range. | In preparation |
| 301 | No connection to the sensor unit. | In preparation |
| 303 | No sensor connected. | In preparation |
| 309 | Sensor cable not connected. | In preparation |
Technical system errors
Do not attempt dangerous self-repair for the following technical errors:
| Code | Meaning | Next step |
|---|---|---|
| 302 | Temperature sensor error | Contact myCistern support. |
| 310 | Fuse blown | Contact myCistern support. Do not repair the circuit board. |
Software update failed
Different technical causes are possible, such as no download, a storage problem, a damaged file, a connection interruption, or a certificate or server error. Safe, realistic steps for end users are limited to:
- Check the WaterGuard internet connection.
- Try again later if the interface allows it.
- If it happens repeatedly, contact myCistern support.
Internal system errors
Errors in the internal file system or configuration files are not suitable for self-service repair. If such an error occurs in the WaterGuard context, contact myCistern support. No instructions for accessing internal file systems are provided.
Error codes that do not apply to WaterGuard Refill
The following codes concern other functional areas or are not relevant to the current WaterGuard Refill:
- 101 – Maximum emptying duration exceeded (emptying function)
- 110 / 111 – Leak protection valve (not implemented for the current WaterGuard Refill)
- 210 / 211 – Irrigation schedule/system (different functional area)
- 240 – Maximum refill quantity exceeded (not implemented for the current WaterGuard Refill)
- 241 – Leak detected (not implemented for the current WaterGuard Refill)
Weather data or inflow forecast is missing
Weather-related codes, such as location detection, undefined collection area, and weather forecast or history, concern weather and forecasting functions and are not the focus of Refill troubleshooting.